ALD112

VDE 1 Form A Slim Power Relay LD LD-RELAYS FEATURES 20.3 .799 7.0 .276 15.0 .591 mm inch 1. Slim type: Width 7 mm .276 inch. 20.3(L)×7.0(W)×15.0(H) mm .799(L)×.276(W)×.591(H) inch 2. Perfect for small load switching of home appliances 105 switching operations possible with a 3A 250V AC resistive load. 3. Low operating power Compact size, nominal operating power as low as 200mW. 4. High ...
развернуть ▼ свернуть ▲
 

Технические характеристики

показать свернуть
Тип контактов
Номинальное напряжение катушки
Тип тока катушки
Мощность катушки максимальная
Номинальный ток коммутации
Коммутируемое напряжение DC (макс)
Коммутируемое напряжение AC (пиковое)
Напряжение изоляции катушка-контакты
Рабочая температура
Размер 20.5×7.2×15.3 мм
Способ подключения выводов
Применение
  Примечания: Power/Signal Relay, 1 Form A, SPST, Momentary, 0.017A (Coil), 12VDC (Coil), 200mW (Coil), 3A (Contact), 30VDC (Contact), DC Input, Random, AC/DC Output, Through Hole-Straight Mount
Магнитная система катушки
Нашли ошибку? Выделите её курсором и нажмите CTRL + ENTER

Аналоги 4

показать свернуть
Тип Наименование Корпус Упаковка i Конфиг Uкатушки AC-DC Pупр(max) Iкомм U dc U ac Изоляция T раб Монтаж Особенности Применение Примечания Тип колодки Магнитная система Семейство Карточка
товара
A- S2EB-L2-12V (PAN)
 
 
Power/Signal Relay, SPST, Latched, 0.017A (Coil), 12VDC (Coil), 200mW (Coil), 3A (Contact), 48VDC (Contact), DC Input, AC/DC Output, PCB Mount-Straight
A- ALDP112W (PAN)
 
 
Power/Signal Relay, 1 Form A, SPST, Momentary, 0.017A (Coil), 12VDC (Coil), 200mW (Coil), DC Input, Random, AC Output, Through Hole-Straight Mount
A- APAN3112 (PAN)
 
1 шт
 
Power/Signal Relay, SPST, Momentary, 0.009A (Coil), 12VDC (Coil), 110mW (Coil), 5A (Contact), 110VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount
A- APF10212 (PAN)
 
 
Power/Signal Relay, 1 Form A, SPST, Momentary, 0.014A (Coil), 12VDC (Coil), 170mW (Coil), DC Input, Random, AC Output, Through Hole-Straight Mount

Файлы 1

показать свернуть
VDE 1 Form A Slim Power Relay LD LD-RELAYS FEATURES 20.3 .799 7.0 .276 15.0 .591 mm inch 1. Slim type: Width 7 mm .276 inch. 20.3(L)×7.0(W)×15.0(H) mm .799(L)×.276(W)×.591(H) inch 2. Perfect for small load switching of home appliances 105 switching operations possible with a 3A 250V AC resistive load. 3. Low operating power Compact size, nominal operating power as low as 200mW. 4. High shock resistance The relay withstands a functional shock resistance of 300m/s2 [approx. 30 G more] 5. High insulation resistance • Creepage distance and clearances between contact and coil: Min. 6 mm .236 inch(In compliance with IEC65) • Surge withstand voltage between contact and coil: 10,000 V or more. 6. UL/CSA, VDE, TÜV approved. SPECIFICATIONS Contact Characteristics Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material Nominal switching capacity Rating (resistive load) Max. switching power Max. switching voltage Max. switching current Mechanical (at 180 cpm) Expected life 3A 125V AC, Electrical (min.operations) (at 20 cpm) 3A 30V DC (at rated load) 3A 250V AC 1 Form A Max. 100 mΩ Silver alloy 3 A 277 V AC, 3 A 30V DC 831 V A (AC), 90W (DC) 277 V AC, 30 V DC 3A 5×106 2×105 20 cpm (at rated load) Min. 1,000 MΩ (at 500 V DC) Operate time*4 (at nominal voltage) Release time (with diode)*4 (at nominal voltage) Max. 10ms (at 20°C 68°F) Temperature rise (at 70°C) 105 Coil Nominal operating power Max. operating speed Initial insulation resistance*1 Between open Initial*2 contacts breakdown Between contact and voltage coil Initial surge voltage between contact and coil*3 Shock resistance 200 mW Remarks • Air conditioner • Refrigerator • Hot water units • Microwave ovens • Fan heaters Min. 10,000 V Max. 10ms (at 20°C 68°F) Max. 45°C with nominal coil voltage and at 3 A contact carrying current (resistance method) Min. 300 m/s2{approx. 30 G} Min. 1,000 m/s2{approx. 100 G} Ambient temp. Humidity 5 to 85% R.H. Vibration resistance Destructive Conditions for operation, transport and storage*8 (Not freezing and condensing at low temperature) Unit weight 4,000 Vrms for 1 min. 10 to 55Hz at double amplitude of 1.5mm 10 to 55Hz at double amplitude of 1.5mm –40°C to +70°C –40°F to +158°F Functional*7 * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Initial breakdown voltage" section. *2 Detection current: 10mA *3 Wave is standard shock voltage of ±1.2×50ms according to JEC-212-1981 *4 Excluding contact bounce time. *5 Half-wave pulse of sine wave: 11 ms; detection time: 10 µs *6 Half-wave pulse of sine wave: 6 ms *7 Detection time: 10 µs *8 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24). TYPICAL APPLICATIONS Functional*5 Destructive*6 750 Vrms for 1 min. Approx. 4 g .141 oz ORDERING INFORMATION Ex. A LD 1 12 Product name Contact arrangement Coil voltage(V DC) LD 1: 1 Form A 4H: 4.5, 09: 9, 24: 24 05: 5, 12: 12 06: 6, 18: 18 UL/CSA, TÜV approved type is standard. Note: Standard packing: Carton: 50pcs, Case: 1,000pcs 47 PDF
Документация на ALD112 

The DatasheetArchive - Datasheet Search Engine http://www.datasheetarchive.com

Дата модификации: 15.08.2007

Размер: 44.8 Кб

3 стр.

    Внимание! Точность указанного на сайте описания товара не может быть гарантирована. Для получения более полной и точной информации о товаре смотрите техническое описание (Datasheet) на сайте производителя.