VDE 250 mW SLIM POWER RELAY 24.0 .945 LK-S LK-S RELAYS FEATURES 11.0 .433 25.0 .984 mm inch Compliance with RoHS Directive 3. High noise immunity realized by the card separation structure between contact and coil 4. Popular terminal pitch in AV equipment field 5. Space-saving slim type Base area: Width 11 × Length 24 mm Width .433 × Length .945 inch 6. Conforms to the various safety s...
развернуть ▼ свернуть ▲
 

Технические характеристики

показать свернуть
Тип контактов
Номинальное напряжение катушки
Тип тока катушки
Мощность катушки максимальная
Номинальный ток коммутации
Коммутируемое напряжение AC (пиковое)
Рабочая температура
Размер 24×11×25 мм
Способ подключения выводов
Применение
  Примечания: Power/Signal Relay, SPST, Momentary, 0.028A (Coil), 9VDC (Coil), 250mW (Coil), DC Input, AC Output, Through Hole-Straight Mount
Магнитная система катушки
Нашли ошибку? Выделите её курсором и нажмите CTRL + ENTER

Файлы 1

показать свернуть
VDE 250 mW SLIM POWER RELAY 24.0 .945 LK-S LK-S RELAYS FEATURES 11.0 .433 25.0 .984 mm inch Compliance with RoHS Directive 3. High noise immunity realized by the card separation structure between contact and coil 4. Popular terminal pitch in AV equipment field 5. Space-saving slim type Base area: Width 11 × Length 24 mm Width .433 × Length .945 inch 6. Conforms to the various safety standards UL/CSA, VDE, TÜV and SEMKO SEV approved 1. High sensitivity: 250mW The power-saving relay is highly sensitive at the nominal operating power of 250 mW (530 mW power consumption on LK relays). 2. High insulation resistance between contact and coil 1) Creepage distance and clearances between contact and coil: Min. 6 mm .236 inch (In compliance with IEC65) 2) Surge withstand voltage between contact and coil: 10,000 V or more SPECIFICATIONS Contact Characteristics Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material Nominal switching capacity Max. switching power Rating Max. switching voltage (resistive load) Max. switching current Min. switching capacity#1 Mechanical (at 180 cpm) Expected life Electrical (at 20 cpm) (min. operations) (at rated load) 1 Form A Max. 100 mΩ AgSnO2 type 5 A 277 V AC 1,385 V A 277 V AC 5 A (AC) 100 mA, 5 V DC 106 Max. operating speed Initial insulation resistance*1 Between open Initial *2 contacts breakdown Between contact and voltage coil Initial surge voltage between contact and coil*3 Operate time*4 (at nominal voltage) Release time (without diode)*4 (at nominal voltage) 105 Temperature rise (at 70°C) Coil Nominal operating power 250 mW #1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. Remarks • Audio visual equipment • Office equipment • Home appliances Functional*7 Vibration resistance * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as “Initial breakdown voltage” section. *2 Detection current: 10mA *3 Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981 *4 Excluding contact bounce time. *5 Half-wave pulse of sine wave: 11 ms; detection time: 10 µs *6 Half-wave pulse of sine wave: 6 ms *7 Detection time: 10 µs *8 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT TYPICAL APPLICATIONS Functional*5 Destructive*6 Shock resistance Destructive Conditions for operation, transport and storage*8 (Not freezing and condensing at low temperature) Ambient temp. Humidity Air pressure 20 cpm (at rated load) Min. 1,000 MΩ (at 500 V DC) 1,000 Vrms for 1 min. 4,000 Vrms for 1 min. Min. 10,000 V Max. 15 ms (at 20°C 68°F) Max. 5 ms (at 20°C 68°F) Max. 35°C with nominal coil voltage and at 5 A contact carrying current (resistance method) Min. 200 m/s2{approx. 20 G} Min. 1,000 m/s2{approx. 100 G} 10 to 55Hz at double amplitude of 1.5mm 10 to 55Hz at double amplitude of 1.5mm –40°C to +70°C –40°F to +158°F 5 to 85% R.H. 86 to 106 kPa Unit weight Approx. 12 g .42 oz ORDERING INFORMATION Ex. LKS 1a F – 12V Contact arrangement Protective construction Coil voltage(DC) 1a: 1 Form A F: Flux-resistant type 5, 6, 9, 12, 18, 24V UL/CSA, TÜV, SEMKO, TV-5 approved type is standard. Notes 1. Standard packing Carton: 100 pcs. Case: 500 pcs. 2. 6 V, 18 V DC types are also available. Please consult us for details. All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. PDF
Документация на LKS1AF-12V 

Mechanical_OP.book

Дата модификации: 26.05.2009

Размер: 75 Кб

3 стр.

    Внимание! Точность указанного на сайте описания товара не может быть гарантирована. Для получения более полной и точной информации о товаре смотрите техническое описание (Datasheet) на сайте производителя.