HL2-HTM-AC12V

HL 15A (1C), 10 A (2C) SPACE SAVING POWER RELAY 20.8 .819 HL RELAYS FEATURES 27.2 1.071 • High switching capacity in a compact size 1 Form C (15 A 125 V AC), 2 Form C (10 A 250 V AC) • Rugged construction for tough applications • Long life Mechanical: Min. 108 operations (DC), Min. 5 × 107 operations (AC) Electrical: Min. 5 × 105 operations 35.4 1.394 mm inch SPECIFICATIONS Contacts Ch...
развернуть ▼ свернуть ▲
 

Технические характеристики

показать свернуть
Тип контактов
Тип тока катушки
Мощность катушки максимальная
Номинальный ток коммутации
Коммутируемое напряжение DC (макс)
Коммутируемое напряжение AC (пиковое)
Рабочая температура
Размер 43×20.6×35.4 мм
Способ подключения выводов
Применение
  Примечания: Power/Signal Relay, DPDT, Momentary, 1200mW (Coil), 10A (Contact), 30VDC (Contact), AC Input, AC/DC Output, Panel Mount
Магнитная система катушки
Нашли ошибку? Выделите её курсором и нажмите CTRL + ENTER

Файлы 1

показать свернуть
HL 15A (1C), 10 A (2C) SPACE SAVING POWER RELAY 20.8 .819 HL RELAYS FEATURES 27.2 1.071 • High switching capacity in a compact size 1 Form C (15 A 125 V AC), 2 Form C (10 A 250 V AC) • Rugged construction for tough applications • Long life Mechanical: Min. 108 operations (DC), Min. 5 × 107 operations (AC) Electrical: Min. 5 × 105 operations 35.4 1.394 mm inch SPECIFICATIONS Contacts Characteristics (at 25°C 77°F, 50% Relative humidity) Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material Nominal switching capacity Max. switching power Rating (resistive) Max. switching voltage Max. switching current Min. switching capacity#1 Expected life Mechanical (at 180 cpm) 15 A 125 V AC Electrical 10 A 250 V (resistive) AC 3 A 30 V DC 1 Form C 2 Form C Max. operating speed Initial insulation resistance*1 50 mΩ Silver alloy 15 A 125 V AC, 10 A 250 V AC 10 A 250 V AC AC: 2,500 VA AC: 2,500 VA DC: 90 W DC: 90 W 250 V AC 250 V AC 30 V DC 30 V DC 15 A 10 A 100 mA, 5 V DC 5×107 (AC), 106 (DC) 5×105 — 5×105 5×105 5×10 5×10 Initial breakdown voltage*2 20 cpm Between contact sets Between open contacts Between contacts and coil Operate time (at nominal voltage) Release time*3 (without diode) (at nominal voltage) Temperature rise, max. (at nominal voltage) Functional*4 Shock resistance Destructive*5 Functional*6 Vibration resistance 5 Destructive 5 #1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. Remarks * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as “Initial breakdown voltage” section *2 Detection current: 10 mA *3 Excluding contact bounce time *4 Half-wave pulse of sine wave: 11ms; detection time: 10µs *5 Half-wave pulse of sine wave: 6ms *6 Detection time: 10µs *7 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT TYPICAL APPLICATIONS Min. 100 MΩ (at 500 V DC) 1,500 Vrms for 1 min. 1,000 Vrms for 1 min. 2,000 Vrms for 1 min. Max. 25 ms (DC type) Max. 25 ms (AC type) Max. 25 ms (DC type) Max. 25 ms (AC type) Max. 80°C Min. 196 m/s2 {20 G} Min. 980 m/s2 {100 G} 10 to 55 Hz at double amplitude of 1 mm 10 to 55 Hz at double amplitude of 2 mm Conditions for operation, Ambient transport and storage*7 temperature (Not freezing and condensing at low Humidity temperature) Unit weight –50°C to +70°C –58°F to +158°F 5 to 85% R.H. Approx. 35 g 1.25 oz ORDERING INFORMATION Power station control equipment, refrigerators, building control equipment, office machines, and medical equipment. Ex. HL Contact arrangement 1: 1 Form C 2: 2 Form C 2 H AC240V Terminal arrangement H: Plug-in HP: PC board HTM: Top mounting L: Light emitting diode wired, plug-in PL: Light emitting diode wired, PC board Note: Standard packing Carton: 20 pcs., Case: 200 pcs. UL/CSA approved type is standard. All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. Coil voltage AC 6, 12, 24, 48, 120, 240 V DC 6, 12, 24, 48, 110 V PDF
Документация на HL1-H-AC240V 

Дата модификации: 18.10.2005

Размер: 149.7 Кб

4 стр.

    Внимание! Точность указанного на сайте описания товара не может быть гарантирована. Для получения более полной и точной информации о товаре смотрите техническое описание (Datasheet) на сайте производителя.