AHES3190

Compact size 2 Form A and 2 Form A 1 Form B 35A power relays for energy management and industrial equipment HE-S RELAYS TYPICAL APPLICATIONS New • Photovoltaic power generation systems (Solar inverter) • Uninterruptible Power Supplies (UPS) • Inverter • Office air conditioner • Industrial equipment RoHS compliant Protective construction: Flux-resistant type FEATURES 1. High-capacity and l...
развернуть ▼ свернуть ▲
 

Технические характеристики

показать свернуть
Применение
Примечания
Магнитная система катушки
Нашли ошибку? Выделите её курсором и нажмите CTRL + ENTER

Файлы 1

показать свернуть
Compact size 2 Form A and 2 Form A 1 Form B 35A power relays for energy management and industrial equipment HE-S RELAYS TYPICAL APPLICATIONS New • Photovoltaic power generation systems (Solar inverter) • Uninterruptible Power Supplies (UPS) • Inverter • Office air conditioner • Industrial equipment RoHS compliant Protective construction: Flux-resistant type FEATURES 1. High-capacity and long life 35A 277V AC 5×104 (long life type) 2. Electrical life (resistive load) Standard type 3×104 — 1×105 Long life type 5×104 1×105 2×105 8. Mirror contact mechanisms (Compliant with EN60947-4-1 mirror contact) 3. Compact size and low operating power W: 30 × L: 36 × H: 40 mm W: 1.181 × L: 1.417 × H: 1.575 inch Operating power: 1,880 mW (holding power: 170 mW) Detection of main contact welding makes it possible to construct a safety circuit. • Designed so that Form A contact and Form B contact will not close at the same time. • When Form A contact welded, Form B contact gap of at least 0.5 mm .020 inch is maintained. 4. Reduced coil holding voltage contributes to saving energy of equipment The coil holding voltage can be reduced up to 30%V of the nominal coil voltage. This equals to operating power of approximately 170 mW, which contributes equipment energy savings. * Form B contact, when used to monitor the condition of Form A contact, can be used exclusively as an auxiliary contact. * Coil holding voltage is the coil voltage after 100 ms from the applied nominal coil voltage. 5. Contact gap: 3.2 mm .126 inch (VDE0126 compliant) Compliant with European photovoltaic standard VDE0126 Compliant with EN61810-1 2.5 kV surge breakdown voltage (between contacts) Conditions Normal operation Non-excitation Form A contact Mirror contact mechanisms Form B contact Excitation Form A contact Form B contact When Form A contact welded Non-excitation Form A contact Form B contact Welding 6. Insulation distance (initial) • Between Form A contact and coil: Min. 11.0 mm .433 inch (Clearance/Creepage) • Between Form B contact and coil: Min. 3.2 mm .126 inch (Clearance/Creepage) • Between Form A contact sets: Min. 8.2 mm .323 inch (Clearance/Creepage) • Between Form A contact and Form B contact: Min. 12.8 mm .504 inch (Clearance/Creepage) –1– ASCTB360E 201604-T Min. 0.5 mm Min. .020 inch Form A contact 35A 277V AC 30A 220V AC 20A 277V AC 7. Contact gap (initial) • Form A contact: Min. 3.2 mm .126 inch/each contact • Form B contact: Min. 0.7 mm .028 inch Min. 0.5 mm .020 inch (When Form A contact welded) PDF
Документация на AHES3190 

HE-S Relays ASCTB360E 201604-T

Дата модификации: 28.04.2016

Размер: 275.4 Кб

7 стр.

    Внимание! Точность указанного на сайте описания товара не может быть гарантирована. Для получения более полной и точной информации о товаре смотрите техническое описание (Datasheet) на сайте производителя.