DTA 9696 R1

Температурный контроллер Delta с ПИД регулятором. 96x96 mm, релейный вых, SPST , 250VAC, 5A, комм.порт RS-485
развернуть ▼ свернуть ▲

Файлы 1

показать свернуть
2005-09-21 CONTROL: Control method setting on the SV display: PID Specifications Http://www.delta.com.tw/industrialautomation 5011615707-DAE7 A Series Temperature Controller Instruction Sheet Thank you very much for purchasing DELTA A Series. Please read this instruction sheet before using your A series to ensure proper operation and please keep this instruction sheet handy for quick reference. Precaution DANGER! Caution! Electric Shock! 1. Do not touch the AC terminals while the power is supplied to the controller to prevent an electric shock. 2. Make sure power is disconnected while checking the unit inside. indicates that this Delta A Series Temperature Controller is 3. The symbol protected throughout by DOUBLE INSULATION or REINFORCED INSULATION (equivalent to Class II of IEC 536). WARNING! This controller is an open-type temperature controller. Make sure to evaluate any dangerous application in which a serious human injury or serious property damage may occur. 1. Always use recommended solder-less terminals: Fork terminal with isolation (M3 screw, width is 7.0mm, hole diameter 3.2mm). Screw size: M3 x 6.5 (With 6.8 x 6.8 square washer). Recommended tightening torque: 0.4 N.m (4kgf.cm). Applicable wire: Solid/twisted wire of 2 mm2, 12AWG to 24AWG. Please be sure to tighten them properly. 2. Do not allow dust or foreign objects to fall inside the controller to prevent it from malfunctioning. 3. Never modify or disassemble the controller. 4. Do not connect anything to the “No used” terminals. 5. Make sure all wires are connected to the correct polarity of terminals. 6. Do not install and/or use the controller in places subject to: • Dust or corrosive gases and liquid. • High humidity. • High radiation. • Vibration and shock. • High voltage and high frequency 7. Must turn power off when wiring and changing a temperature sensor. 8. Be sure to use compensating wires that match the thermocouple types when extending or connecting the thermocouple wires. 9. Please use wires with resistance when extending or connecting a platinum resistance thermometer (RTD). 10. Please keep the wire as short as possible when wiring a platinum resistance thermometer (RTD) to the controller and please route power wires as far as possible from load wires to prevent interference and induced noise. 11. This controller is an open-type unit and must be placed in an enclosure away from high temperature, humidity, dripping water, corrosive materials, airborne dust and electric shock or vibration. 12. Please make sure power cables and signals from instruments are all installed properly before energizing the controller, otherwise serious damage may occur. 13. Please do not touch the terminals in the controller or try to repair the controller when power is applied to prevent an electric shock. 14. Wait at least one minute after power is disconnected to allow capacitors to discharge, and please do not touch any internal circuit within this period. 15. Do not use acid or alkaline liquids for cleaning. Please use a soft, dry cloth to clean the controller. 16. This instrument is not furnished with a power switch or fuse. Therefore, if a fuse or power supply switch is required, install the protection close to the instrument. Recommended fuse rating: Rated voltage 250 V, Rated current 1 A. Fuse type: Time-lag fuse Note: This controller does not provide overcurrent protection. Use of this product requires that suitable overcurrent protection device(s) must be added to ensure compliance with all relevant electrical standards and codes. (Rated 250 V, 15 Amps max). A suitable disconnecting device should be provided near the controller in the end-use installation. ( Input Voltage Operation Voltage Range Power Consumption 100 to 240VAC 50/60Hz 85% to 110% of rated voltage 5VA max. 7-segment digit LED Display Process value (PV): Red color, Set point (SV): Green color Thermocouple: K, J, T, E, N, R, S, B, U, L, Txk 3-wire Platinum RTD: Pt100, JPt100 PID, ON/OFF control or Manual tuning Relay output:(resistive load): SPDT (SPST: 1/16 DIN size), 250VAC, 5A Voltage Pulse output: DC 14V, Max. load current 40mA Current output: 4 to 20mADC (Load resistance: Max. 600Ω) 0.1% of measuring range 500 msec/per scan 10 to 55Hz, 10m/s2 for 10min, each in X, Y and Z directions Max. 300m/ s2, 3 times in each 3 axes, 6 directions Display Method Sensor Type Control Mode Control Output Display Accuracy Sampling Rate Vibration Resistance Shock Resistance Ambient Temperature Storage Temperature Relative Humidity Altitude o o 0 C to +50 C o o -20 C to +65 C 35% to 80% (non-condensing) 2000m or less Installation Category 33, Pollution Degree 2. Conforming to EN61010-1 Installation Environment Parameters List 1. Operation Mode: Perform per the settings of related control parameters LED Display Explanation ( ) or Stop ) mode on the SV display. ALARM1 HIGH: Upper-limit alarm 1 : Mode key. Press this key to set parameters within each function mode. • o o o C, F : Temperature unit LEDs. C LED lights when this parameter is configured for o Celsius and F LED lights if configured for Fahrenheit. • ALM1 / ALM2 : Alarm output LED. The ALM1 / ALM2 LED lights when Alarm 1 or Alarm 2 output is ON. • : Up key. Press this key to increase values displayed on the SV display. Hold down this key to speed up the incremental action. • : Down key. Press this key to decrease values displayed on the SV display. Hold down this key to speed up the decrements. 0 C WE: Write-in function disable/enable OFF (Displayed when using serial communication) C NO: Address setting 1 (Displayed when using serial communication) BPS: Baud rate setting 9600 (Displayed when using serial communication) LENGTH: Data length setting 7 (Displayed when using serial communication) PARITY: Parity bit setting E (Displayed when using serial communication) STOP BIT: Stop bit setting 1 (Displayed when using serial communication) Note: Alarm values should be set in the initial setting mode so AL1H, AL1L, AL2H and AL2L would display in operation mode. Temperature Sensor Type and Temperature Range Input Temperature Sensor Type Register Value LED Display Temperature Range o -20.0 to 500.0 C Platinum resistance (Pt100) type1 13 -200 to 600 C Platinum resistance (JPt100) type2 12 0.0 to 100.0 C Platinum resistance (JPt100) type1 11 -20.0 to 400.0 C Thermocouple (TC) B type 10 100 to 1800 C Thermocouple (TC) S type 9 0 to 1700 C Thermocouple (TC) R type 8 0 to 1700 C 7 o OFF Thermocouple (TC) N type o o o o o -200 to 1300 C Thermocouple (TC) E type 6 0 to 600 C Thermocouple (TC) T type2 5 -20.0 to 400.0 C Thermocouple (TC) T type1 4 -200 to 400 C Thermocouple (TC) J type2 3 -20.0 to 400.0 C o 2 -100 to 850 C Thermocouple (TC) K type2 1 -20.0 to 500.0 C Thermocouple (TC) K type1 0 -200 to 1300 C 17 -200 to 500 C D: Derivative Time (PID control) 41 Thermocouple (TC) Txk type 18 -200 to 800 C 0 0 3. Initial Setting Mode: Initial settings of the controller and communication parameters o UNIT: Temperature display unit, C ( o ) and F ( Default PT2 o ) o 16 C T-HIGH: Upper limit for temperature range 500.0 T-LOW: Lower limit for temperature range -20.0 Press Control setting RUN or STOP Press Upper-limit alarm 1 (This parameter is available only when ALA1 function enables) Set temperature unit Press Set upper-limit of temperature range Press Set lower-limit of temperature range Lower-limit alarm 1 or P/PD control Offset setting (When PID control is ON and Ki=0, Upper-limit alarm 2 set the value of PdoF; If Ki≠0, AT will automatically set the value of (This parameter is available only when ALA2 function enables) ioF Press Press (This parameter is available only when ALA1 function enables) Press Press Select control method Press Select heating/cooling functions Press or Heating/Cooling hysteresis (In ON/OFF control) Press Lower-limit alarm 2 (This parameter is available only when ALA2 function enables) Press Alarm 1 setting Press Alarm 2 setting Set Heating/Cooling control cycle (In PID control) Setting lock mode Regulate temperature deviation value Press Press Press Output value display and adjust Press Write-in function disable/enable (Displayed when using serial communication) Press Press Address setting CT function is selected Regulate 20mA output (Displayed when using serial In case of using an external CT, deviation value communication) the controller displays the current (Display when current output) value being measured by CT, if Press the control output is ON. Press Press -200 to 850 C Baud rate setting o o Regulate 4mA output deviation value (Display when current output) Return to temperature display (Displayed when using serial communication) Press Press Temperature sensor is Measured temperature value Unknown input not connected exceeds the temperature range Return to auto-tuning setting SV 0 0 Set PID Td (In PID control) o PV CRLO: Regulate 4mA output deviation value Explanation INPUT: Select input temperature sensor type (Please refer to the contents of the “Temperature Sensor Type and Temperature Range” for detail) o Input Error Indication Setting value Press Press o o Thermocouple (TC) J type1 Thermocouple (TC) L type Set input type Press o Thermocouple (TC) U type 0 Press set temperature of target o 260 CRHI: Regulate 20mA output deviation value Set PID Ti (In PID control) or 47.6 0 Press to o I: Integral Time (PID control) TPOF: Regulate temperature deviation value Set PID PB (In PID control) Use o P: Proportional Band (PID control) Output Selection: V: 4 sec. R: 20 sec. Press Initial Setting Mode Operation Mode 0.0 to 100.0 C OFF 0 (In PID control and RUN mode) Heating and Cooling Control Temperature control is achieved either by heating or by cooling. The heating function starts when the process temperature (PV) is going down, and the cooling function when the temperature is getting high. It is impossible to operate both functions simultaneously in this controller. AT: Auto-tuning setting. When AT key is set to ON ( ), the execution of the PID auto-tuning function is automatically started. (PID control) CLPD: PID cooling control cycle setting (PID control) LED Display AL2 SET: Alarm 2 setting Default HTPD: PID heating control cycle setting (PID control) • 0 Explanation PdoF: Offset output when P or PD control function is ON. (PID control and Ki=0) ioF: Default value of integral volume when PID control function is ON and integral time constant is not equal to 0(zero). AT can automatically set this parameter. (PID control and Ki≠0) HTS: Set Heating hysteresis when ON/OFF control function is ON. CTS: Set Cooling hysteresis when ON/OFF control function is ON. : Function key. 1. Press this key to select the desired function mode. 2. Press this key to confirm a setting value. AL1 SET: Alarm 1 setting o 2. Regulation Mode: Set the control parameters • PV Display : to display the process value or parameter type. • SV Display : to display set point, parameter operation read value, manipulated variable or set value of the parameter. • AT : flashes when the Auto-tuning operation is ON. • OUT : lights when the output is ON. HEAT 14 press and key simultaneously, the “Lock” status can be released and the controller will be back to the previous display. OUT: Output value display and output value adjustment in manual tuning control (This function is not available in 0 ON/OFF control or Auto-tuning setting) CT: In case of using an external current transformer (CT), the controller displays the current value being measured by CT, if Read only the control output is ON LED Display ) 15 ) or OFF Regulation Mode Auto-tuning ) or Cooling ( Platinum resistance (Pt100) type2 4.0 C ), Lock 2 ( ) Platinum resistance (Pt100) type3 o ) on the SV display. Lock 1 mode can lock all settings ( and Lock 2 mode only can lock others than SV value. When OFF mode is selected, the Lock function will be OFF. If you PID o 4.0 C ALARM2 LOW: Lower-limit alarm 2 ), or manual tuning o 4.0 C ALARM2 HIGH: Upper-limit alarm 2 Display, LED and Pushbuttons • RUN 4.0 C ALARM1 LOW: Lower-limit alarm 1 Setting lock: Lock 1 ( ( SWITCH: Select Heating ( action Default RUN/STOP: Control setting begins. Run ( ), ON/OFF control ( Data length setting (Displayed when using serial communication) Press Operation There are three modes of operation: operation, regulation and initial setting. When power key to switch to Parity bit setting key is pressed for more than 3 seconds, controller will switch (Displayed when using serial communication) is applied, controller gets into the operation mode. Press the regulation mode. If the to the initial setting mode. Pressing the key while in the regulation mode or initial setting mode, forces the controller to return to the operation mode. PV/SV: Sets the temperature set point and displays the temperature process value. Use the and Press keys to set the temperature set point. Setting method: While in any function mode, press the key to select the desired function and use the and keys to change settings. Press key to save the changes. The next flow chart shows how to switch for settings and internal functions: Press key less than 3 sec Press key more than 3 sec Operation Mode Regulation Mode Press key Initial Setting Mode Press key Stop bit setting (Displayed when using serial communication) Press Return to input type setting PDF
Документация на DTA 4848 R1 

Microsoft Word - 5011615707-DAE7_0923.doc

Дата модификации: 23.09.2005

Размер: 1.08 Мб

2 стр.

    Внимание! Точность указанного на сайте описания товара не может быть гарантирована. Для получения более полной и точной информации о товаре смотрите техническое описание (Datasheet) на сайте производителя.